Full version · coming soon

Window installation thermal bridges, calculated for your own detail.

The full version of the Window Installation Thermal Bridge Documentation Tool: your own wall build-up, any frame position and insulation overlap, all frame profiles, a live 2-D calculation, the condensation check and a complete report.

Calculation2-D steady state, ISO 10211, validated against its test cases
ValidationISO 10077-2 Annex D: 10 of 10 cases within ±3 %
Wall U-valueISO 6946

Launch: coming soon. Registered users hear first.

What only the full version does · calculated in real time

Your own wall build-up

Change a material's λ (the layer colour follows) or add a layer — the wall U-value (ISO 6946) and Ψ follow straight away.

Illustrative animation · sample wall

LayermmλRender100.80Mineral wool2500.0350.032Brick1750.45Lime plaster150.80Wood fibre board600.040+ Add layerU = 0.137 W/(m²K)U = 0.118 W/(m²K)

Any frame profile

Choose PVC, timber, timber-aluminium or aluminium profiles — standard or passive house. Here the PVC frame is swapped for an aluminium passive-house profile.

frame
PVC passive house, foam-filledAluminium passive house, thermally broken
same position and insulation · materials view

9 profile families in the full version · sections from the calculation model

exteriorinterior
PVC passive house, foam-filled ▾Aluminium passive house, thermally broken ▾
PVC passive house, foam-filled
PVC standard, steel reinforced
Timber passive house, PU core
Timber-aluminium passive house
Timber IV 88, triple glazing
Timber IV 78, triple glazing
Timber IV 68, double glazing
Aluminium passive house, thermally broken
Aluminium, standard thermal break

Drag the frame, stretch the insulation

Move the frame through the wall and pull the insulation over the frame. Ψ is recalculated as you drag.

{{ what }}
Ψ {{ psiTxt }} W/(mK)
frame position {{ pTxt }} mm · insulation over the frame {{ ovTxt }} mm

Calculated by the full version · masonry wall, PVC passive-house frame, head · 2-D, ISO 10211

exteriorinterior

Live isotherms

The temperature field and its 1 K isotherms follow every change — see where the heat leaves.

{{ what }}
Ψ {{ psiTxt }} W/(mK)
θi 20 °C · θe −10 °C · Rsi 0.13 / Rse 0.04

Calculated by the full version · masonry wall, PVC passive-house frame, head · 2-D, ISO 10211

exteriorinterior

fRsi and the condensation line

With the surface resistance for condensation (Rsi 0.25) the tool finds the coldest interior point and draws the dew-point isotherm; the dot marks the minimum surface temperature.

coldest interior point
fRsi {{ fTxt }}
θsi,min {{ thTxt }} · purple line = 9.3 °C isotherm, dew point at 20 °C / 50 % RH (θe −10 °C, Rsi 0.25)

Calculated by the full version · masonry wall, PVC passive-house frame, head · 2-D, ISO 10211

9.3 °C{{ thTxt }}exteriorinterior

The report, in one click

Materials and boundary conditions, Ψ with isotherms and the fRsi page — A4, ready to save as PDF for the certifier, with your logo.

Create report

Pages from the full version · results of the case shown in the other demos

Window installation thermal bridge1 / 3
Materials and boundary conditions
Wall U-value0.120 W/(m²K)
FramePVC passive house, D 85 mm
Insulation over frame58 mm
Window installation thermal bridge2 / 3
Ψ install, isotherms 1 K
Ψ install0.000 W/(mK)
θi / θe20 / −10 °C
Rsi / Rse0.13 / 0.04
Window installation thermal bridge3 / 3
fRsi and condensation
fRsi0.942
θsi,min18.3 °C
Dew point (20 °C, 50 %)12.6 °C

From documenting a catalogue case to calculating your detail

The free edition documents your detail against the Energieinstitut Vorarlberg catalogue. The full version calculates the detail you actually build.

The 2-D steady-state calculation follows ISO 10211 and is validated against the ISO 10211 test cases and the ten reference cases of ISO 10077-2, Annex D (all within ±3 %).

Free editionFull version
Catalogue case from the EIV catalogue, values unchanged
Documentation report as PDF
Your own wall build-up, U-value per ISO 6946
Any frame position and insulation overlap
All frame profiles, incl. aluminium and standard PVC
Live calculation of Ψ install (2-D, ISO 10211)
Condensation check with fRsi
Brackets and fixings in the model

Register your interest

Tell us who you are and how you would use it. We will write to you when the full version opens, and invite a few registered users to test it before launch.

We only use your email to tell you about the full version. You can unsubscribe with one click. Privacy notice

Write to us to join the list

Send us your name, your role and how you would use the full version. We will add you to the list and write to you when it opens.

Open the contact form

Thank you — you are on the list.

We will email you when the full version opens. Meanwhile the free edition is ready to use.

Open the free edition