{"id":2932,"date":"2026-10-07T14:04:24","date_gmt":"2026-10-07T12:04:24","guid":{"rendered":"https:\/\/zepassiv.com\/?p=2932"},"modified":"2026-10-07T16:05:47","modified_gmt":"2026-10-07T14:05:47","slug":"guia-passivhaus-airtightness-blower-door","status":"publish","type":"post","link":"https:\/\/zepassiv.com\/pt\/guia-passivhaus-airtightness-blower-door\/","title":{"rendered":"Hermeticidad Passivhaus y ensayo Blower Door: gu\u00eda completa (EN ISO 9972)"},"content":{"rendered":"<p class=\"wp-block-paragraph\"><strong>Autor: Jes\u00fas Men\u00e9ndez<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em><strong>PHI Certified Passivhaus Consultant (CPC)&nbsp; \u00b7&nbsp; PHI Certifier&nbsp; \u00b7&nbsp; PHPP Expert Instructor<\/strong><\/em><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Qu\u00e9 es la hermeticidad en edificios Passivhaus<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La hermeticidad (o impermeabilidad al aire) es la capacidad de la envolvente de un edificio de <strong>evitar que el aire exterior entre sin control<\/strong> a trav\u00e9s de grietas, juntas, encuentros y penetraciones. En un edificio convencional, las infiltraciones de aire representan hasta el <strong>30\u201340 % de las p\u00e9rdidas de calor<\/strong> en invierno.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En el est\u00e1ndar Passivhaus, la hermeticidad es uno de los <strong>cinco pilares fundamentales<\/strong> junto con el aislamiento, los puentes t\u00e9rmicos, las ventanas de alto rendimiento y el sistema de ventilaci\u00f3n con recuperaci\u00f3n de calor (MVHR). Sin una envolvente herm\u00e9tica, la ventilaci\u00f3n mec\u00e1nica con recuperaci\u00f3n de calor no funciona correctamente y el balance energ\u00e9tico del edificio se deteriora.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>El par\u00e1metro n50: c\u00f3mo se mide la hermeticidad<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">El resultado de un ensayo Blower Door se expresa habitualmente como <strong>n50<\/strong> (tasa de renovaciones de aire por hora a 50 Pascales de presi\u00f3n diferencial). Tambi\u00e9n puede expresarse como <strong>q50<\/strong> (caudal de infiltraci\u00f3n por unidad de superficie de envolvente, en m\u00b3\/h\u00b7m\u00b2).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La norma de referencia internacional es la EN ISO 9972:2015 (Comportamiento higrot\u00e9rmico de edificios \u2014 Determinaci\u00f3n de la permeabilidad al aire de los edificios \u2014 M\u00e9todo de presurizaci\u00f3n por ventilador), que define el procedimiento, los equipos, las condiciones de validez y el c\u00e1lculo de resultados.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Contexto \/ Normativa<\/strong><\/td><td><strong>Par\u00e1metro<\/strong><\/td><td><strong>Umbral m\u00e1ximo<\/strong><\/td><\/tr><tr><td><strong>Passivhaus Classic (PHI)<\/strong><\/td><td>n50<\/td><td>\u2264 0,6 reh\/h@50Pa<\/td><\/tr><tr><td><strong>Passivhaus Plus \/ Premium (PHI)<\/strong><\/td><td>n50<\/td><td>\u2264 0,6 reh\/h@50Pa (mismo que Classic)<\/td><\/tr><tr><td><strong>EnerPHit \u2014 rehabilitaci\u00f3n (PHI)<\/strong><\/td><td>n50<\/td><td>\u2264 1,0 reh\/h@50Pa<\/td><\/tr><tr><td><strong>CTE DB-HE (Espa\u00f1a) \u2014 obra nueva<\/strong><\/td><td>n50 \/ q50<\/td><td>No fija umbral n50 expl\u00edcito; regulaci\u00f3n indirecta v\u00eda C100<\/td><\/tr><tr><td><strong>Edificios convencionales (referencia)<\/strong><\/td><td>n50<\/td><td>5\u201315 reh\/h@50Pa (sin sellado activo)<\/td><\/tr><tr><td><strong>Edificio de construcci\u00f3n media Espa\u00f1a<\/strong><\/td><td>n50<\/td><td>3\u20138 reh\/h@50Pa (estimaci\u00f3n t\u00edpica)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Referencia: <a href=\"https:\/\/www.iso.org\/standard\/55718.html\" target=\"_blank\" rel=\"noopener\">EN ISO 9972:2015 \u2014 Passive House Institute<\/a> \u00b7 <a href=\"https:\/\/passivehouse.com\/02_informations\/02_enerphit\/02_enerphit.htm\" target=\"_blank\" rel=\"noopener\">Criterios PHI EnerPHit<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Procedimiento del ensayo Blower Door (EN ISO 9972)<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">El ensayo se divide en tres fases: preparaci\u00f3n, medici\u00f3n y an\u00e1lisis de resultados.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"960\" height=\"1045\" src=\"https:\/\/zepassiv.com\/wp-content\/uploads\/Zepassiv_BD_Infog1_Fases_Procedimiento-1.png\" alt=\"\" class=\"wp-image-2934\" title=\"\" srcset=\"https:\/\/zepassiv.com\/wp-content\/uploads\/Zepassiv_BD_Infog1_Fases_Procedimiento-1.png 960w, https:\/\/zepassiv.com\/wp-content\/uploads\/Zepassiv_BD_Infog1_Fases_Procedimiento-1-941x1024.png 941w, https:\/\/zepassiv.com\/wp-content\/uploads\/Zepassiv_BD_Infog1_Fases_Procedimiento-1-367x400.png 367w, https:\/\/zepassiv.com\/wp-content\/uploads\/Zepassiv_BD_Infog1_Fases_Procedimiento-1-768x836.png 768w, https:\/\/zepassiv.com\/wp-content\/uploads\/Zepassiv_BD_Infog1_Fases_Procedimiento-1-11x12.png 11w\" sizes=\"(max-width: 960px) 100vw, 960px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Fase 1 \u2014 Preparaci\u00f3n del edificio<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Antes del ensayo, el edificio debe estar en &#8216;modo test&#8217;: todas las aperturas intencionales (conductos de ventilaci\u00f3n, chimeneas, rejillas) selladas temporalmente; puertas interiores abiertas; ventanas y puertas exteriores cerradas. Las aperturas no intencionales (grietas, juntas) permanecen sin sellar \u2014 son precisamente lo que se mide.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Fase 2: Instalaci\u00f3n del equipo y medici\u00f3n<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">El equipo Blower Door consta de un ventilador calibrado, un marco ajustable y sensores de presi\u00f3n y caudal. Se instala habitualmente en la puerta principal del edificio. El procedimiento seg\u00fan <a href=\"https:\/\/www.iso.org\/standard\/55718.html\" target=\"_blank\" rel=\"noopener\">EN ISO 9972<\/a> somete al edificio a presiones de \u00b110 a \u00b160 Pa en 5\u201310 puntos de medici\u00f3n en presurizaci\u00f3n y despresurizaci\u00f3n.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Paso<\/strong><\/td><td><strong>Acci\u00f3n<\/strong><\/td><td><strong>Par\u00e1metro registrado<\/strong><\/td><\/tr><tr><td><strong>1<\/strong><\/td><td>Medici\u00f3n de caudal en ventilador a 50 Pa (presurizaci\u00f3n)<\/td><td>V\u030750+ (m\u00b3\/h)<\/td><\/tr><tr><td><strong>2<\/strong><\/td><td>Medici\u00f3n de caudal a 50 Pa (despresurizaci\u00f3n)<\/td><td>V\u030750- (m\u00b3\/h)<\/td><\/tr><tr><td><strong>3<\/strong><\/td><td>Media de ambas mediciones<\/td><td>V\u030750 medio<\/td><\/tr><tr><td><strong>4<\/strong><\/td><td>Divisi\u00f3n por volumen interior presurizado<\/td><td>n50 (reh\/h)<\/td><\/tr><tr><td><strong>5<\/strong><\/td><td>Registro de condiciones (viento, temperatura)<\/td><td>Verificaci\u00f3n de validez EN ISO 9972<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Fase 3: An\u00e1lisis y detecci\u00f3n de fugas<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Una vez obtenido el resultado, si el n50 no cumple el umbral objetivo, el equipo de ensayo realiza una localizaci\u00f3n de fugas mediante humo de trazado o c\u00e1mara termogr\u00e1fica (en condiciones de diferencia de temperatura interior\/exterior suficiente). Las fugas principales se categorizan y se define un plan de sellado antes de repetir el ensayo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Preguntas de IA cubiertas:<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>\u2192 c\u00f3mo se hace el ensayo blower door<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>\u2192 procedimiento prueba presurizaci\u00f3n edificio<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>\u2192 qu\u00e9 equipo se usa en el ensayo blower door<\/em><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Cu\u00e1ndo realizar el ensayo Blower Door en un proyecto Passivhaus<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">En un proyecto Passivhaus o EnerPHit se recomienda realizar al menos dos ensayos:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Momento del ensayo<\/strong><\/td><td><strong>Objetivo<\/strong><\/td><td><strong>Beneficio<\/strong><\/td><\/tr><tr><td><strong>Durante obra \u2014 previo al trasdosado<\/strong><\/td><td>Detectar y sellar fugas antes de tapar<\/td><td>Evita tener que abrir paredes una vez terminadas; coste de correcci\u00f3n mucho menor<\/td><\/tr><tr><td><strong>Al finalizar la obra (ensayo final)<\/strong><\/td><td>Obtener el resultado oficial para certificaci\u00f3n<\/td><td>Resultado n50 certificable; obligatorio para PHI<\/td><\/tr><tr><td><strong>Ensayo opcional post-ocupaci\u00f3n<\/strong><\/td><td>Verificar que no ha habido p\u00e9rdida de hermeticidad<\/td><td>Recomendado tras 1\u20132 a\u00f1os de uso si hay anomal\u00edas en consumo<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"868\" height=\"1080\" src=\"https:\/\/zepassiv.com\/wp-content\/uploads\/Zepassiv_BD_Infog2_Cuando_Realizar-1-868x1080.png\" alt=\"\" class=\"wp-image-2936\" title=\"\" srcset=\"https:\/\/zepassiv.com\/wp-content\/uploads\/Zepassiv_BD_Infog2_Cuando_Realizar-1-868x1080.png 868w, https:\/\/zepassiv.com\/wp-content\/uploads\/Zepassiv_BD_Infog2_Cuando_Realizar-1-823x1024.png 823w, https:\/\/zepassiv.com\/wp-content\/uploads\/Zepassiv_BD_Infog2_Cuando_Realizar-1-322x400.png 322w, https:\/\/zepassiv.com\/wp-content\/uploads\/Zepassiv_BD_Infog2_Cuando_Realizar-1-768x955.png 768w, https:\/\/zepassiv.com\/wp-content\/uploads\/Zepassiv_BD_Infog2_Cuando_Realizar-1-10x12.png 10w, https:\/\/zepassiv.com\/wp-content\/uploads\/Zepassiv_BD_Infog2_Cuando_Realizar-1.png 960w\" sizes=\"(max-width: 868px) 100vw, 868px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Para la <a href=\"https:\/\/zepassiv.com\/pt\/certificacao-passivhaus-2\/\">certifica\u00e7\u00e3o Passivhaus<\/a>, el \u00fanico ensayo v\u00e1lido es el ensayo final, realizado con el edificio completamente terminado y con las instalaciones en su estado definitivo. El resultado debe estar documentado en el informe de ensayo y enviado junto con el modelo PHPP al PHI Certifier.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Precio orientativo del ensayo Blower Door en Espa\u00f1a<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">El precio del ensayo Blower Door var\u00eda seg\u00fan el tipo de edificio, su volumen, la accesibilidad y el laboratorio o empresa que realiza el servicio. Los rangos siguientes son <strong>orientativos<\/strong>:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Tipo de edificio \/ ensayo<\/strong><\/td><td><strong>Precio orientativo*<\/strong><\/td><td><strong>Notas<\/strong><\/td><\/tr><tr><td><strong>Vivienda unifamiliar (hasta 500 m\u00b3)<\/strong><\/td><td>400 \u2013 700 \u20ac<\/td><td>Ensayo simple (presurizaci\u00f3n + despresurizaci\u00f3n)<\/td><\/tr><tr><td><strong>Vivienda grande o chalet (500\u20131.500 m\u00b3)<\/strong><\/td><td>600 \u2013 950 \u20ac<\/td><td>Puede requerir 2 ventiladores en paralelo<\/td><\/tr><tr><td><strong>Edificio plurifamiliar (&lt;10 viviendas)<\/strong><\/td><td>900 \u2013 1.800 \u20ac<\/td><td>Ensayo por unidad o del edificio completo<\/td><\/tr><tr><td><strong>Edificio plurifamiliar o terciario (&gt;10 unidades)<\/strong><\/td><td>Consultar<\/td><td>Presupuesto espec\u00edfico seg\u00fan volumen y accesibilidad<\/td><\/tr><tr><td><strong>Ensayo con termograf\u00eda simult\u00e1nea<\/strong><\/td><td>+300 \u2013 500 \u20ac<\/td><td>Localizaci\u00f3n de fugas t\u00e9rmicas con c\u00e1mara IR<\/td><\/tr><tr><td><strong>Repetici\u00f3n post-sellado<\/strong><\/td><td>150 \u2013 350 \u20ac<\/td><td>Verificaci\u00f3n tras correcciones; no siempre necesaria<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"960\" height=\"1061\" src=\"https:\/\/zepassiv.com\/wp-content\/uploads\/Zepassiv_BD_Infog3_Precios-1.png\" alt=\"Precio del Ensayo Blower Door en Espa\u00f1a\" class=\"wp-image-2938\" title=\"\" srcset=\"https:\/\/zepassiv.com\/wp-content\/uploads\/Zepassiv_BD_Infog3_Precios-1.png 960w, https:\/\/zepassiv.com\/wp-content\/uploads\/Zepassiv_BD_Infog3_Precios-1-927x1024.png 927w, https:\/\/zepassiv.com\/wp-content\/uploads\/Zepassiv_BD_Infog3_Precios-1-362x400.png 362w, https:\/\/zepassiv.com\/wp-content\/uploads\/Zepassiv_BD_Infog3_Precios-1-768x849.png 768w, https:\/\/zepassiv.com\/wp-content\/uploads\/Zepassiv_BD_Infog3_Precios-1-11x12.png 11w\" sizes=\"(max-width: 960px) 100vw, 960px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>* Precios orientativos, por confirmar. <\/strong>El precio final depende del laboratorio, el volumen del edificio, el desplazamiento del t\u00e9cnico y si se requiere termograf\u00eda. <a href=\"https:\/\/zepassiv.com\/pt\/ensayo-blower-door\/\">Solicita presupuesto \u2192<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Hermeticidad en rehabilitaci\u00f3n EnerPHit: retos espec\u00edficos<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">En proyectos de rehabilitaci\u00f3n <a href=\"https:\/\/zepassiv.com\/pt\/enerphit\/\">EnerPHit<\/a>, alcanzar el umbral \u2264 1,0 reh\/h@50Pa es m\u00e1s complejo que en obra nueva porque el edificio ya tiene penetraciones, juntas envejecidas y detalles constructivos hist\u00f3ricos dif\u00edciles de sellar. Los retos m\u00e1s habituales son:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Encuentros entre la membrana nueva de hermeticidad y los elementos estructurales existentes<\/strong><\/li>\n\n\n\n<li>Penetraciones de instalaciones existentes (tuber\u00edas, cableado, bajantes) sin manguitos de sellado<\/li>\n\n\n\n<li>Cajas de persianas, fraileros y capialzados \u2014 puntos de fuga muy frecuentes en edificios espa\u00f1oles<\/li>\n\n\n\n<li>Juntas en carpinter\u00edas existentes que se conservan parcialmente<\/li>\n\n\n\n<li>Forjados que conectan el interior con el exterior sin barrera de aire continua<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">La clave en EnerPHit es <strong>dise\u00f1ar la l\u00ednea de hermeticidad antes de empezar la obra<\/strong> y formarla en el plano de ejecuci\u00f3n, de forma que los industriales sepan exactamente d\u00f3nde y c\u00f3mo ejecutar los sellados. Esta coordinaci\u00f3n la realiza el consultor Passivhaus con experiencia en rehabilitaci\u00f3n.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/zepassiv.com\/pt\/enerphit\/\">Quieres saber m\u00e1s sobre EnerPHit vista esta gu\u00eda\u2192<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Preguntas frecuentes sobre el ensayo Blower Door<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>\u00bfEs el ensayo Blower Door obligatorio para certificar Passivhaus?<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">S\u00ed. El <a href=\"https:\/\/passivehouse.com\/\" target=\"_blank\" rel=\"noopener\">Instituto Passivhaus<\/a> exige el ensayo Blower Door (seg\u00fan <a href=\"https:\/\/www.iso.org\/standard\/55718.html\" target=\"_blank\" rel=\"noopener\">EN ISO 9972<\/a>) como parte obligatoria del proceso de certificaci\u00f3n, tanto para Passivhaus Classic como para EnerPHit. Sin el informe de ensayo, no puede emitirse el certificado.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>\u00bfPuede realizarse el ensayo Blower Door en cualquier \u00e9poca del a\u00f1o?<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">S\u00ed, aunque las condiciones afectan a la validez. La norma EN ISO 9972 establece l\u00edmites de velocidad de viento exterior (&lt; 6 m\/s) y de diferencia de temperatura interior-exterior para que el ensayo sea v\u00e1lido. En general, los d\u00edas tranquilos de oto\u00f1o e invierno son ideales; los d\u00edas muy ventosos o de pleno verano pueden requerir horarios ajustados.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>\u00bfQu\u00e9 pasa si el edificio no supera el ensayo Blower Door?<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Si el resultado n50 supera el umbral admisible, el edificio no puede certificarse hasta que se corrija la hermeticidad. El proceso habitual es: localizaci\u00f3n de fugas con humo o termograf\u00eda \u2192 sellado de los puntos detectados \u2192 repetici\u00f3n del ensayo. Este es el motivo por el que se recomienda el ensayo previo al trasdosado: las correcciones son mucho m\u00e1s sencillas y econ\u00f3micas antes de tapar.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>\u00bfEl ensayo Blower Door detecta todos los problemas de hermeticidad?<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">El Blower Door cuantifica el total de infiltraciones pero no localiza autom\u00e1ticamente las fugas. Para identificar los puntos problem\u00e1ticos se combina con humo de trazado (visible en presurizaci\u00f3n) o con termograf\u00eda infrarroja (en despresurizaci\u00f3n con suficiente diferencia t\u00e9rmica interior\/exterior). Zepassiv puede coordinar ambos servicios en la misma visita.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>\u00bfQu\u00e9 diferencia hay entre n50 y q50?<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">n50 es el n\u00famero de renovaciones de aire por hora del volumen interior a 50 Pa (depende del cociente volumen\/envolvente). q50 es el caudal de fuga por metro cuadrado de envolvente a 50 Pa (m\u00b3\/h\u00b7m\u00b2). Para edificios de gran volumen y poca envolvente (edificios plurifamiliares altos), q50 es un indicador m\u00e1s equitativo que n50. El PHI usa habitualmente n50 como criterio de certificaci\u00f3n.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Puntos clave<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>El ensayo Blower Door es <strong>obligatorio para la certificaci\u00f3n Passivhaus<\/strong>, tanto Classic (\u2264 0,6 reh\/h@50Pa) como EnerPHit (\u2264 1,0 reh\/h@50Pa)<\/li>\n\n\n\n<li>El procedimiento est\u00e1 regulado por la norma <a href=\"https:\/\/www.iso.org\/standard\/55718.html\" target=\"_blank\" rel=\"noopener\">EN ISO 9972:2015<\/a>; su incumplimiento invalida el ensayo<\/li>\n\n\n\n<li>Se recomienda un ensayo previo al trasdosado (durante obra) y otro final (para certificaci\u00f3n)<\/li>\n\n\n\n<li>El precio es orientativo: 400\u2013950 \u20ac para vivienda unifamiliar, m\u00e1s termograf\u00eda opcional<\/li>\n\n\n\n<li>En rehabilitaci\u00f3n EnerPHit, el dise\u00f1o previo de la l\u00ednea de hermeticidad es determinante para alcanzar el umbral<\/li>\n\n\n\n<li>Zepassiv coordina ensayo, termograf\u00eda y coordinaci\u00f3n con el PHI Certifier: <a href=\"https:\/\/zepassiv.com\/pt\/ensayo-blower-door\/\">servicio completo \u2192<\/a><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u00bfNecesitas ensayo Blower Door para tu proyecto Passivhaus?&nbsp; \u2192&nbsp; <\/strong><a href=\"https:\/\/zepassiv.com\/pt\/contato\/\"><strong>Solicitar presupuesto \u2192<\/strong><\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Fuentes y referencias<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2197 <a href=\"https:\/\/www.iso.org\/standard\/55718.html\" target=\"_blank\" rel=\"noopener\">EN ISO 9972:2015 \u2014 Hermeticidad de edificios<\/a> \u2014 Norma internacional que define el procedimiento del ensayo Blower Door (fan pressurisation); establece los par\u00e1metros n50 y q50 y los criterios de validez del ensayo<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2197 <a href=\"https:\/\/passivehouse.com\/\" target=\"_blank\" rel=\"noopener\">Passive House Institute (PHI)<\/a> \u2014 Organismo que fija los umbrales de hermeticidad para certificaci\u00f3n Passivhaus (\u2264 0,6 reh\/h@50Pa Classic; \u2264 1,0 reh\/h@50Pa EnerPHit) y el procedimiento de verificaci\u00f3n<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2197 <a href=\"https:\/\/passivehouse.com\/02_informations\/02_enerphit\/02_enerphit.htm\" target=\"_blank\" rel=\"noopener\">PHI \u2014 EnerPHit Standard<\/a> \u2014 Criterios oficiales de hermeticidad para la certificaci\u00f3n EnerPHit (\u2264 1,0 reh\/h@50Pa) y requisitos del ensayo Blower Door en proyectos de rehabilitaci\u00f3n<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2197 <a href=\"https:\/\/www.aivc.org\/\" target=\"_blank\" rel=\"noopener\">AIVC \u2014 Air Infiltration and Ventilation Centre<\/a> \u2014 Centro internacional de investigaci\u00f3n sobre ventilaci\u00f3n e infiltraci\u00f3n de aire en edificios; publicaciones t\u00e9cnicas sobre hermeticidad y sus efectos en la calidad del aire y la eficiencia energ\u00e9tica<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2197 <a href=\"https:\/\/www.codigotecnico.org\/\" target=\"_blank\" rel=\"noopener\">C\u00f3digo T\u00e9cnico de la Edificaci\u00f3n (CTE) \u2014 DB-HE<\/a> \u2014 Marco normativo espa\u00f1ol; el CTE establece requisitos m\u00ednimos de hermeticidad para obra nueva, que el est\u00e1ndar Passivhaus supera con creces<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2197 <a href=\"https:\/\/database.passivehouse.com\/\" target=\"_blank\" rel=\"noopener\">PHI Certified Products Database<\/a> \u2014 Cat\u00e1logo de membranas, cintas y materiales de hermeticidad certificados por el PHI, con valores de permeabilidad verificados<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2197 <a href=\"https:\/\/www.idae.es\/\" target=\"_blank\" rel=\"noopener\">IDAE \u2014 Instituto para la Diversificaci\u00f3n y Ahorro de la Energ\u00eda<\/a> \u2014 Informaci\u00f3n sobre eficiencia energ\u00e9tica en edificios en Espa\u00f1a; la hermeticidad es un factor clave en las convocatorias de rehabilitaci\u00f3n energ\u00e9tica<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Autor: Jes\u00fas Men\u00e9ndez PHI Certified Passivhaus Consultant (CPC)&nbsp; \u00b7&nbsp; PHI Certifier&nbsp; \u00b7&nbsp; PHPP Expert Instructor Qu\u00e9 es la hermeticidad en edificios Passivhaus La hermeticidad (o impermeabilidad al aire) es la capacidad de la envolvente de un edificio de evitar que el aire exterior entre sin control a trav\u00e9s de grietas, juntas, encuentros y penetraciones. En [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":2940,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1,39],"tags":[],"class_list":["post-2932","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","category-blower-door"],"acf":[],"_links":{"self":[{"href":"https:\/\/zepassiv.com\/pt\/wp-json\/wp\/v2\/posts\/2932","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zepassiv.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zepassiv.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zepassiv.com\/pt\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/zepassiv.com\/pt\/wp-json\/wp\/v2\/comments?post=2932"}],"version-history":[{"count":3,"href":"https:\/\/zepassiv.com\/pt\/wp-json\/wp\/v2\/posts\/2932\/revisions"}],"predecessor-version":[{"id":2939,"href":"https:\/\/zepassiv.com\/pt\/wp-json\/wp\/v2\/posts\/2932\/revisions\/2939"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zepassiv.com\/pt\/wp-json\/wp\/v2\/media\/2940"}],"wp:attachment":[{"href":"https:\/\/zepassiv.com\/pt\/wp-json\/wp\/v2\/media?parent=2932"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zepassiv.com\/pt\/wp-json\/wp\/v2\/categories?post=2932"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zepassiv.com\/pt\/wp-json\/wp\/v2\/tags?post=2932"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}